- Home
 - > Cable
 - > Marine Cable
 
SFOI(i) screened fire resistant instrumentation cable
SFOI(i) screened fire resistant instrumentation cable
SFOI(i) screened fire resistant instrumentation cable application
This cable is designed for telephone & instrument circuits up to 150/250V.
Suitable for use in commercial marine applications
Maximum conductor temperature : 90℃
SFOI(i) screened fire resistant instrumentation cable standards
Design Guide : IEC 60092-350, 376
Insulation Material : IEC 60092-351
Sheath Material : IEC 60092-359
	Flammability : IEC 60332-1 & 
IEC 60332-3 Category A        
Fire Resistance : IEC 60331 (750℃or 1000℃)
Halogen Content : IEC 60754-1,2, 0.5%(Max.)Smoke Emission : IEC 61034-1,2, 60%(Min.)
SFOI screened fire resistant instrumentation cable model
150/250V SFOI(c)
150/250V SFOI(i)
150/250V SFOI(i&c)
SFOI screened fire resistant instrumentation cable construction
	
 
| Classification | Code | Construction detail | 
| Conductor | 
				 | 
			Stranded plain annealed copper wires as per IEC 60228, Class 2 | 
| Fire resisting layer | S | Mica/glass tape | 
| Insulation | XLPE as per IEC 60092-351 | |
| Twisting | 
				 | 
			Two/Three Insulated cores shall be twisted together to form a pair/triad | 
| Individual screen | (i) | 
				- Screened by AL/PS tape with tinned copper drain wire - Each pair/triad is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triads  | 
		
| Cabling | 
				 | 
			
				- Screened pairs/triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable  | 
		
| Collective screen | (c) | 
				- Screened by AL/PS tape with tinned copper drain wire - A suitable tape may be applied on the collective screen - In case of 250V BI(i)cable, collective screen is omitted - SHF1 as per IEC 60092-359  | 
		
| Inner Covering | F | Non-hygroscopic material | 
| Armor | O | 
				- Braid of plain annealed copper wire - Coverage density : Min. 90%  | 
		
| Sheath | I | 
				- Sheath color : Black - Colored insulation plus Arabic number printing on the insulation  | 
		
| Core identification | 
				 | 
			Pair : White, Black Triad : White, Red, Black | 
The other color of sheath and insulation may be applicable when purchaser required.
Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.
SFOI screened fire resistant instrumentation cable specification
Cores: 1P, 2P,3P,4P,5P,7P,10P,12P,14P,16P,19P,20P, 24P, 30P (P:Pair)
1T, 2T,3T,4T,5T,7T,10T,12T,14T,16T,19T,20T, 24T, 30T (Triad)
Size (sqmm): 0.75, 1, 1.5, 2.5
SFOI screened fire resistant instrumentation cable show
	
 
Cable Sample
	
 
Workshop
	
 
Testing Lab
Society certificates
	