Overview
CB/T907-94 Marine Bronze Male Thread Angle Liquid Safety Valves are spring-loaded automatic safety relief valves for ship piping systems and pressure vessels. They remain closed normally and open automatically to release excess pressure once the system pressure reaches the preset set pressure, to protect piping and equipment from overpressure damage. This valve is male thread connection complying with CB56 thread standard. It covers DN10–DN25 with adjustable set pressure range from 0.1 MPa to 3.2 MPa. Suitable for fresh water, seawater, lube oil and fuel oil up to 190℃. Cast aluminum bronze body and cover, QA19-2 disc and spring assembly. Install in vertical or horizontal liquid pipelines. Each valve is pressure and performance tested per GB/T 600 and CB 3021. Confirm set pressure and thread size before ordering; the set pressure shall be specified according to working conditions.
Basic Sructure of Marine Bronze Angle Safety Valve

1 — Body, 2 — Disc, 3 — Spring, 4 — Bonnet
Basic parameters(CB 907-1994 )
| Working Pressure P
MPa |
Nominal Diameter DN
mm |
Service media |
|---|---|---|
| 0.1~0.25 | 10~25 | fresh water, seawater, lube oil and fuel oil up to 190℃. |
| >0.25~0.6 | 10~25 | |
| >0.6~0.9 | 10~25 | |
| >0.9~1.2 | 10~25 | |
| >1.2~1.6 | 10~25 | |
| >1.6~2.5 | 10~25 | |
| >2.5~3.2 | 10~25 |
Working principle
Spring preload holds the disc closed. When medium pressure exceeds the set pressure, the disc lifts for overpressure relief. It reseats automatically by spring force once pressure falls below reseating pressure. No external control required.
Basic dimensions(CB 907-1994 )
| PN
(MPa) |
DN
(mm) |
Structure dimension | Flange connection dimension | ||||||||
| L | D | H1 | H | D1 | D2 | D3 | L1 | L2 | L3 | ||
| 0.1~0.25 | 10 | 40 | 55 | 30 | 138 | 13 | 19.8 | M22×1.5 | 17 | 2 | 2 |
| >0.25~06 | 10 | 40 | 55 | 30 | 138 | 13 | 19.8 | M22×1.5 | 17 | 2 | 2 |
| >0.6~0.9 | 10 | 40 | 55 | 30 | 138 | 13 | 19.8 | M22×1.5 | 17 | 2 | 2 |
| >0.9~1.2 | 10 | 40 | 55 | 30 | 140 | 13 | 19.8 | M22×1.5 | 17 | 2 | 2 |
| >1.2~1.6 | 10 | 40 | 55 | 30 | 140 | 13 | 19.8 | M22×1.5 | 17 | 2 | 2 |
| >1.6~2.5 | 10 | 42 | 55 | 34 | 146 | 14 | 24.8 | M27×1.5 | 19 | 3 | 3 |
| >2.5~3.2 | 10 | 42 | 55 | 34 | 149 | 14 | 24.8 | M27×1.5 | 19 | 3 | 3 |
| 0.1~0.25 | 15 | 48 | 58 | 40 | 148 | 19 | 27.0 | M30×2 | 23 | 3 | 2 |
| >0.25~06 | 15 | 48 | 58 | 40 | 148 | 19 | 27.0 | M30×2 | 23 | 3 | 2 |
| >0.6~0.9 | 15 | 48 | 58 | 40 | 148 | 19 | 27.0 | M30×2 | 23 | 3 | 2 |
| >0.9~1.2 | 15 | 48 | 58 | 40 | 155 | 19 | 27.0 | M30×2 | 23 | 3 | 2 |
| >1.2~1.6 | 15 | 48 | 58 | 40 | 155 | 19 | 27.0 | M30×2 | 23 | 3 | 2 |
| >1.6~2.5 | 15 | 50 | 58 | 45 | 162 | 22 | 33.0 | M36×2 | 26 | 5 | 3 |
| >2.5~3.2 | 15 | 50 | 58 | 45 | 162 | 22 | 33.0 | M36×2 | 26 | 5 | 3 |
| 0.1~0.25 | 20 | 55 | 72 | 44 | 170 | 24 | 33.0 | M36×2 | 23 | 3 | 2 |
| >0.25~06 | 20 | 55 | 72 | 44 | 170 | 24 | 33.0 | M36×2 | 23 | 3 | 2 |
| >0.6~0.9 | 20 | 55 | 72 | 44 | 170 | 24 | 33.0 | M36×2 | 23 | 3 | 2 |
| >0.9~1.2 | 20 | 55 | 72 | 44 | 170 | 24 | 33.0 | M36×2 | 23 | 3 | 2 |
| >1.2~1.6 | 20 | 55 | 72 | 44 | 170 | 24 | 33.0 | M36×2 | 23 | 3 | 2 |
| >1.6~2.5 | 20 | 60 | 72 | 48 | 176 | 25 | 36.0 | M39×2 | 27 | 5 | 3 |
| >2.5~3.2 | 20 | 60 | 72 | 48 | 186 | 25 | 36.0 | M39×2 | 27 | 5 | 3 |
| 0.1~0.25 | 25 | 60 | 80 | 46 | 190 | 29 | 39.0 | M42×2 | 24 | 3 | 2 |
| >0.25~06 | 25 | 60 | 80 | 46 | 190 | 29 | 39.0 | M42×2 | 24 | 3 | 2 |
| >0.6~0.9 | 25 | 60 | 80 | 46 | 190 | 29 | 39.0 | M42×2 | 24 | 3 | 2 |
| >0.9~1.2 | 25 | 60 | 80 | 46 | 190 | 29 | 39.0 | M42×2 | 24 | 3 | 2 |
| >1.2~1.6 | 25 | 60 | 80 | 46 | 197 | 29 | 39.0 | M42×2 | 24 | 3 | 2 |
| >1.6~2.5 | 25 | 67 | 80 | 55 | 203 | 32 | 45.0 | M48×2 | 30 | 6 | 3 |
| >2.5~3.2 | 25 | 67 | 80 | 55 | 210 | 32 | 45.0 | M48×2 | 30 | 6 | 3 |
| Part Name | Material — Name | Material — Grade | Standard No. |
|---|---|---|---|
| Body | Aluminum bronze | ZQAL9‑2 | CB883‑89 |
| Bonnet | Aluminum bronze | QAL9‑2 | GB4429‑84 |
| Disc | Aluminum bronze | QAL9‑2 | GB4429‑84 |
| Spring | Carbon spring steel wire | Grade C | GB4357‑89 |
Selection & Installation Key Points
1.Selection: For liquid only (fresh water, seawater, lube oil, fuel oil), ≤190℃, DN10‑DN25, set pressure range 0.1~3.2 MPa. Reserve enough margin between working pressure and set pressure; high temperature reduces pressure margin.
2.Installation orientation: Spring bonnet vertical upward. Allowed on horizontal or vertical liquid pipelines. FORBIDDEN: inverted, horizontal spring orientation or heavy tilt.
3.Seat: Metal‑to‑metal aluminum bronze sealing face, for clean liquid only.
4.Temp‑pressure: Set pressure calibrated at ambient temperature. Temperature rise impacts spring performance; keep operating pressure ≥10% below set pressure.
5.Flow & clearance: Inlet straight, outlet 90° side discharge. Keep clear space above bonnet for adjustment and overhaul; outlet unobstructed to safe zone.
Why this valve
Two functions in one body: the disc is the pressure‑relieving element, the spring assembly is the load‑setting element. With the spring adjusted to the preset set pressure, once medium pressure exceeds the set value, the disc lifts and the valve discharges overpressure; when pressure drops below the reseating pressure, the disc reseats automatically. One thread connection, one set of sealing pairs, one item in the spare parts list.It opens without external command. Rising system pressure overcomes spring load and lifts the disc — no air supply, no solenoid, no signal from the control system. The same pressure surge that endangers the pipeline or vessel is what opens the valve.The simple spring structure is the maintenance argument. The bonnet can be removed for spring replacement and set pressure calibration, with clear access to internal disc and sealing face; no need to dismantle adjacent piping heavily.Wetted parts are fixed at order: ZQAL9‑2 cast aluminum bronze body, QAL9‑2 aluminum bronze bonnet and disc, Grade C carbon spring steel wire spring, metal‑to‑metal sealing face, suitable for fresh water, seawater, lube oil and fuel oil up to 190℃.What it is not: a control valve or stop valve. The disc lifts only when overpressure occurs; it is not held part‑open to throttle flow, and it cannot be used for flow isolation under normal working conditions.