AWS E8015-C2 Low Temperature Steel Electrode
	W907Ni 
	GB:E5515-C2
AWS:E8015-C2
Current:Used for welding 3.5Ni low temperature low-alloy steel structures under -90��.
	
		
			
	AWS:E8015-C2
Current:Used for welding 3.5Ni low temperature low-alloy steel structures under -90��.
| W907Ni | According with GB E5515-C2 Corresponding with AWS E8015-C2 | ||||||||||||||
| 
						 | |||||||||||||||
| 
						 | |||||||||||||||
| Chemical Composition of Deposited Metal (%) 
 | |||||||||||||||
| Mechanical Properties of Deposited Metal 
 | |||||||||||||||
| Diffusible Hydrogen Content in Deposited Metal: ≤6.0ml/100g(Glycerine Hydrogen Test) | |||||||||||||||
| X-ray Radiographic Inspection: ⅠDegree | |||||||||||||||
| Reference Current (DC+) 
 | |||||||||||||||
| Instructions: 1.The electrodes must be baked under about 350℃ for an hour before welding, and used as soon as baking is completed. 2.The weldments must be preheated under about 150℃ before welding to avoid cracks. 3.If the stress in the weldments needs eliminating, they should be tempered under 600-650℃ after welding. |  | ||||||||||||||