Features
Model YZB combine panel for marine and industrial use
. Compact structure, centralized monitoring: Multiple pressure gauges are integrated on a compact panel, saving space and enabling simultaneous observation of pressure at multiple points.
. Strong environmental adaptability: The panel and wetted parts are made of 316 stainless steel or heavy-duty powder-coated steel, providing resistance to corrosion, vibration, salt spray, and humidity fluctuations; protection rating can reach IP54 to IP65 (splash- and dust-proof).
. High maintenance safety: Each gauge position can be equipped with an independent shut-off valve, test cock, or dampener, facilitating safe maintenance and accurate readings without shutting down the system.
. Flexible configuration: Available in single and double configurations, with optional needle valves and other valves; spring dampeners can be added as needed to suppress pressure pulsation.
. Complete certifications: Can be supplied with certifications from classification societies such as CCS, ABS, DNV, LR, and BV.
Measuring Range
Model YZB combine panel for marine/industrial use
The measuring range is very wide, covering applications from micro-pressure to ultra-high pressure. One product datasheet gives a nominal range of -100 to 60,000 MPa. It should be noted that this is a very broad general nominal value; in actual selection, an independent pressure gauge with a suitable range should be selected according to the specific working conditions (medium, temperature, pressure fluctuation). Its working ambient temperature is usually -25°C to 70°C (or -20°C to 60°C).
CryoCombo cryogenic panel
. Pressure gauge range: Optional 10, 15, 25, 40, or 60 bar, with a PSI secondary scale.
. Level gauge (differential pressure) range: Minimum 0-30 in. H₂O (approx. 0-700 mmHg), maximum 0-1400 in. H₂O (approx. 0-35,000 mmHg).
. Maximum line pressure: 750 PSI (50 bar); minimum burst pressure is 3000 psig (200 bar) (hydrostatically tested).
. Temperature range: Standard maximum temperature is 200°F (93°C); consult the manufacturer for cryogenic applications.
. Accuracy: Calibrated accuracy is ±2% of full scale, and repeatability is ±1%.
Dimensions
The dimensions of the Model YZB marine/industrial combine panel mainly depend on the dial diameter and single/double configuration. The specific overall dimensions (L×H₁×H₂×B, in mm) are as follows:
| Model | Dial diameter (mm) | L (mm) | H₁ (mm) | H₂ (mm) | B (mm) |
| Single | Φ60 | 100 | 60 | 120 | — |
| Φ75 | 120 | 72 | 128 | — | |
| Φ100 | 145 | 85 | 140 | — | |
| Double | Φ60 | 200 | 60 | 120 | 90 |
| Φ75 | 260 | 72 | 128 | 95 | |
| Φ100 | 285 | 85 | 140 | 145 |